Sandwich element
Top installed, sandwich structure
Top installed frame and 160mm handrail with vertical bracket | |
With top installed frame (päällekiinnitettävä paarre), the minimum overhang of edge wall is 30mm, recommended 50mm DET.1 Vertical bracket is to be anchored 117-137mm from slab edge DET.2 Horizontal bracket is to be anchored 142-162mm from slab edge DET.2 Dewatering through the slab edge Handrail wall brackets' adjustment range is +-10mm vertically and +-25mm in depth |
Top installed frame and 160mm handrail with vertical bracket, 90° railing | |
· With top installed frame, the minimum overhang of edge wall is 30mm, recommended 50mm DET.1 · Vertical bracket is anchored 117-137mm from the slab edge DET.2 Horizontal bracket is to be anchored 142-162mm from slab edge. Element seal inside the balcony glazing, bracket anchoring distance must be at least 80mm. DET 3 With horizontal bracket the minimum distance from slab edge is 75mm. · Dewatering through the slab edge Dewatering through the slab edge · Handrail wall brackets' adjustment range is +-10mm vertically and +-25mm in depth With handrail wall brackets, the height adjustment is +-10mm and depth adjustment +-25mm |
Top installed frame and 160mm handrail with vertical bracket | |
· With top installed frame, the minimum overhang of edge wall is 30mm, recommended 50mm DET.1 · Vertical brackets are to be anchored 117-137mm from slab edge DET. 2 · Pillarbracket DET.4. 131-329mm from slab edge · Dewatering through the slab edge · Handrail wall brackets' adjustment range is +-10mm vertically and +-25mm in depth |
Top installed frame and 160mm handrail with vertical bracket | |
Element seal is to be inside the balcony glazing, bracket anchoring distance must be at least 80mm. DET 3 With horizontal bracket the minimum distance from slab edge is 75mm. |
Details
Laatan sivuun kiinnitys, sandwich rakenne
Side installed frame and 160mm handrail with vertical bracket | |
With side installed frame, the minimum overhang of [edge wall] is 50mm, recommended 80mm. DET. 11 Vertical bracket is to be anchored 78-98mm from slab edge DET. 12. Horizontal bracket is to be anchored 103-123mm from slab edge. Any element seals are to be inside the balcony glazing and vertical bracket's anchoring distance at least 80mm. DET. 13. Dewatering with a system inside the balcony Handrail wall brackets' adjustment range is +-10mm vertically and +-25mm in depth |
Side installed frame and 160mm handrail with vertical bracket, 90° railing | |
With side installed frame, the minimum overhang of [edge wall] is 50mm, recommended 80mm. DET. 11 Vertical bracket is to be anchored 78-98mm from slab edge Horizontal bracket is to be anchored 103-123mm from slab edge. Any element seals are to be inside the balcony glazing and vertical bracket's anchoring distance at least 80mm. DET. 13. Dewatering with a system inside the balcony Handrail wall brackets' adjustment range is +-10mm vertically and +-25mm in depth |
Side installed frame and 160mm handrail with vertical bracket | |
With side installed frame, the minimum overhang of edge wall is 50mm, recommended 80mm. DET. 11 Vertical bracket is to be anchored 78-98mm from slab edge DET. 12. Pillar bracket DET. 14 91-298mm from slab edge Any element seals are to be inside the balcony glazing and vertical bracket's anchoring distance at least 80mm. DET. 13. Dewatering with a system inside the balcony Handrail wall brackets' adjustment range is +-10mm vertically and +-25mm in depth |
Side installed frame and 160mm handrail with vertical bracket | |
Element seal is to be inside the balcony glazing, bracket anchoring distance must be at least 80mm. DET 13 With horizontal bracket the minimum distance from slab edge is 75mm. |
Details