Sandwich element

Top installed, sandwich structure

Top installed frame and 160mm handrail with vertical bracket

With top installed frame (päällekiinnitettävä paarre), the minimum overhang of edge wall is 30mm, recommended 50mm DET.1

Vertical bracket is to be anchored 117-137mm from slab edge DET.2

Horizontal bracket is to be anchored 142-162mm from slab edge DET.2

Dewatering through the slab edge

Handrail wall brackets' adjustment range is +-10mm vertically and +-25mm in depth

Top installed frame and 160mm handrail with vertical bracket, 90° railing

· With top installed frame, the minimum overhang of edge wall is 30mm, recommended 50mm DET.1

· Vertical bracket is anchored 117-137mm from the slab edge DET.2

Horizontal bracket is to be anchored 142-162mm from slab edge.

Element seal inside the balcony glazing, bracket anchoring distance must be at least 80mm. DET 3 With horizontal bracket the minimum distance from slab edge is 75mm.

· Dewatering through the slab edge Dewatering through the slab edge

· Handrail wall brackets' adjustment range is +-10mm vertically and +-25mm in depth With handrail wall brackets, the height adjustment is +-10mm and depth adjustment +-25mm

Top installed frame and 160mm handrail with vertical bracket

· With top installed frame, the minimum overhang of edge wall is 30mm, recommended 50mm DET.1

· Vertical brackets are to be anchored 117-137mm from slab edge DET. 2

· Pillarbracket DET.4. 131-329mm from slab edge

· Dewatering through the slab edge

· Handrail wall brackets' adjustment range is +-10mm vertically and +-25mm in depth

Top installed frame and 160mm handrail with vertical bracket
Element seal is to be inside the balcony glazing, bracket anchoring distance must be at least 80mm. DET 3 With horizontal bracket the minimum distance from slab edge is 75mm.

Details

Laatan sivuun kiinnitys, sandwich rakenne

Side installed frame and 160mm handrail with vertical bracket

With side installed frame, the minimum overhang of [edge wall] is 50mm, recommended 80mm. DET. 11

Vertical bracket is to be anchored 78-98mm from slab edge DET. 12.

Horizontal bracket is to be anchored 103-123mm from slab edge.

Any element seals are to be inside the balcony glazing and vertical bracket's anchoring distance at least 80mm. DET. 13.

Dewatering with a system inside the balcony

Handrail wall brackets' adjustment range is +-10mm vertically and +-25mm in depth

Side installed frame and 160mm handrail with vertical bracket, 90° railing

With side installed frame, the minimum overhang of [edge wall] is 50mm, recommended 80mm. DET. 11

Vertical bracket is to be anchored 78-98mm from slab edge

Horizontal bracket is to be anchored 103-123mm from slab edge.

Any element seals are to be inside the balcony glazing and vertical bracket's anchoring distance at least 80mm. DET. 13.

Dewatering with a system inside the balcony

Handrail wall brackets' adjustment range is +-10mm vertically and +-25mm in depth

Side installed frame and 160mm handrail with vertical bracket

With side installed frame, the minimum overhang of edge wall is 50mm, recommended 80mm. DET. 11

Vertical bracket is to be anchored 78-98mm from slab edge DET. 12.

Pillar bracket DET. 14 91-298mm from slab edge

Any element seals are to be inside the balcony glazing and vertical bracket's anchoring distance at least 80mm. DET. 13.

Dewatering with a system inside the balcony

Handrail wall brackets' adjustment range is +-10mm vertically and +-25mm in depth

Side installed frame and 160mm handrail with vertical bracket
Element seal is to be inside the balcony glazing, bracket anchoring distance must be at least 80mm. DET 13 With horizontal bracket the minimum distance from slab edge is 75mm.

Details